null
svg-arrow-next svg-arrow-prev
×
sidebar

Philips HeartStart OnSite AED Ready-Pack - CALL FOR SPRING PRICING SPECIALS 1 800 260 6362

SKU:
M5066A Opt. R01
Availability:
IN-STOCK and ready to ship.
Weight:
20.00 LBS

CALL FOR SPRING PRICING SPECIALS 1 800 260 6362

Norton Etrust Authorized.net Accredited Business

The HeartStart OnSite Defibrillator comes with:

  • 2 Sets Adult SMART Pads cartridge
  • Battery (lasts 4 years)
  • Standard Carry Case
  • Quick Reference Guide
  • 8-year warranty

GIFT WITH PURCHASE (inspection tag, facility sticker, maintenance checklist)
FREE MAINTENANCE PROGRAM! Receive notifications of expiring consumables along with one-on-one customer service and support. Owning an AED has never been easier!

*The Infant/Child pads cartridge is sold separately.

 
Simple to operate - Turns on with easy-to-use pull handle

Every HeartStart OnSite comes ready-to-rescue. The device is pre-installed in the carrying case and battery and pads are pre-installed in the device. Simply pull up the handle on the front of the AED to activate it.

 
Guided audio instruction - Talks you through your training

The HeartStart OnSite provides on-demand audio coaching. Calm, clear voice instructions are tailored to the responder’s actions, providing AED and CPR guidance during the resuscitation of a sudden cardiac arrest victim.

 
SMART Biphasic therapy - Safely delivers maximum shock strength

Philips SMART Biphasic therapy uses a unique combination of high current - to maximize effectiveness, and a lower energy dose - to minimize side effects that are harmful to a fragile heart.

 
Built-in self test - Ready when needed

Your HeartStart OnSite goes through a 120-point test before it leaves the factory. On the job, it conducts self tests every single day, not just weekly. It performs over 80 different tests in all. Even the pads are tested for readiness.

 
Quick Shock feature - Minimize chest compression interruptions

CPR is even more vital to survival than previously realized. Rapidly delivering a shock after chest compressions is critical. The HeartStart OnSite’s Quick Shock feature reduces the time between hands-off and shock delivery.

 
Integrated SMART pads - Senses application to patient skin

The pads are "smart" because they can sense that they have been removed from the cartridge and applied to the patient. This helps the HeartStart OnSite know at what point the user is in the response process.

 
 Visual queues - Clear, intuitive icon driven operation

The HeartStart OnSite’s graphics-based visual instructions are designed to communicate instantly, with minimum reading and interpretation. Users not fluent in the device’s language can follow easily.

 

 

Product Specifications

   
Defibrillator Number HeartStart M5066A
Defibrillator Family HS1
How Supplied

Defibrillator, battery (one, preinstalled), SMART Pads (one, preinstalled), Set-up/Maintenance guide with expiration date tags, Owner’s Manual, Quick Reference Guide.
 
HeartStart Onsite (HS1) Ready-Pack option R01:  Defibrillator inside carry case, battery (one, pre-installed), SMART Pads (one set pre-installed plus spare set in carry case), Set-up/Maintenance guide with expiration date tags, Owner’s Manual, Quick Reference Guide.

Waveform Truncated Exponential Biphasic. Waveform parameters adjusted as a function of each patient’s impedance.
Therapy Adult defibrillation peak current: 32A (150J nominal) into a 50 ohm load. Pediatric defibrillation (with optional Infant/Child SMART Pads Cartridge): 19A (50J nominal) into a 50 ohm load.
Shock-to-Shock Cycle Time Typically less than 20 seconds between shocks in a series.
Quick Shock Able to deliver a shock after the end of a CPR interval, typically in eight seconds.
Voice Instructions Detailed voice messages guide responder through use of the defibrillator.
CPR Coaching Instructions for adult and infant/child CPR available at user’s option.
Shock Delivery Via adhesive pads placed on patient’s bare skin as illustrated on pads.
Controls Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock button.
Indicators Ready light; blue i-button; caution light.

Physical Requirements

   
Sealing Solid objects per EN60529 class IP2X Drip-proof per EN60529 class IPX1
Temperature

Operating: 32º - 122º F (0º - 50º C)

Standby: 50º - 109º F (10º - 43º C)

Humidity

Operating: 0% to 95% relative, non-condensing

Standby: 0% to 75% relative, non-condensing

Altitude

Operating: 0 to 15,000 ft (0 to 4,500 m)
Standby: 0 to 8,500 ft > 48 hours and 8,500 to 15,000 feet < 48 hours

Shock/Drop Abuse Withstands 1 meter drop to any edge, corner or surface.
Vibration Meets EN1789 random and swept sine, road ambulance specification in operating and standby states.
EMI (Radiated/Immunity) Meets EN55011 Group 1 Level B Class B and EN61000-4-3.

Patient Analysis System

   
Patient Analysis Evaluates patient ECG to determine if a rhythm is shockable. Rhythms considered shockable are ventricular fibrillation (VF) and certain ventricular tachycardias (VT) associated with lack of circulation. For safety reasons, some VT rhythms associated with circulation will not be interpreted as shockable, and some very low-amplitude or low-frequency rhythms will not be interpreted as shockable VF.
Sensitivity/Specificity Meets AAMI DF80 guidelines and AHA recommendations for adult defibrillation (Circulation 1997;95:1677-1682).
Artifact Detection The effects of pacemaker artifact and electrical noise are minimized with artifact detection.
Battery Type(M5070A) 9 Volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells.
Capacity Minimum 200 shocks or 4 hours of operating time (EN 60601-2-4:2003)
Install-By-Date Battery is labeled with an install-by date of at least five years from date of manufacture.
Standby Life Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified standby Temperature range, assuming one battery insertion test and no defibrillation uses.)

SMART Pads

   
Adult SMART Pads Cartridge M5071A defibrillation pads for patients 8 years of age and older or 55 lbs. (25 kg) and over.
Infant/Child SMART Pads Cartridge M5072A defibrillation pads for patients under 8 years of age or 55 lbs. (25 kg). Rx only.
Energy Delivered

Adult: nominal 150 Joules into a 50 ohm load
Infant/Child: nominal 50 Joules into a 50 ohm load

How Supplied Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution.
Active Surface Area 13.2 in² (85 cm²) each
Cable Length

Adult pads: 54 in (137.1 cm)
Infant/Child pads: 40 in (101.6 cm)

Use-by Date Cartridge is labeled with a use-by date of at least two years from date of manufacture.

Training Pads

   
Adult Training Pads Cartridge M5073A
Infant/Child Training Pads Cartridge M5074A
Function Special pads put HeartStart OnSite into training mode and disable its energy delivery capability. Training pads feature 8 real-world training scripts. Used with training mat (included) or with adapters on manikins.

Automated and User Activated Self-Tests

   
Daily Automatic Self-Tests Tests internal circuitry, waveform delivery system, pads cartridge and battery capacity.
Pads Integrity Test Specifically tests readiness-for-use of pads (gel moisture).
Battery Insertion Test Upon battery insertion, extensive automatic self-tests and user-interactive test check device readiness.
Status Indicator Blinking green "Ready" light indicates ready for use. Audible “chirp” indicates need for maintenance.

Data Recording and Transmission

   
Infared Wireless transmission of event data to a PC or Palm® PDA, using the IrDA protocol.
Data Stored First 15 minutes of ECG and the entire incident’s events and analysis decisions.

 

 

 

 

HeartStart Home Defibrillator Philips will replace or repair the HeartStart Home Defibrillator, model M5068A, within eight years of the original retail purchase (for products shipped after December 1, 2011) if it is found to be defective in materials or workmanship. This warranty, applicable only to home installations, is valid for the original retail purchaser from the date of initial retail purchase. Save your receipt as proof of date of purchase. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Replacement or repair will be at Philips' sole discretion. HeartStart Home Accessories Philips will replace or repair accessories for the HeartStart Home Defibrillator within the specified warranty period if found to be defective in materials or workmanship or if it does not meet the specifications published by Philips. The battery is warranted for 4 years from the date of installation. The SMART Pads cartridge is warranted until the expiration date listed on the cartridge. All other accessories are warranted for 1 year from the date of purchase. This warranty is valid for the original purchaser from the date of initial retail purchase. Save your receipt as proof of date of purchase. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. For All HeartStart Products What is not covered under warranty: normal wear and tear; products that are modified or subjected to unusual physical or electrical stress; misuse; neglect; alteration; improper installation, repair or testing. All HeartStart products must be used in accordance with instructions for use and properly serviced as required in the owner's manual in order to be eligible for warranty protection. How to Obtain Warranty Service For prompt warranty service, call 1.866.DEFIBHOME (1.866.333.4246). A customer service representative will give you detailed instructions on how to fulfill your HeartStart Home Defibrillator warranty. Implied Warranties Any implied warranties, including implied warranties of merchantability and fitness for a particular purpose, shall be limited to the duration of the express warranties set forth in this limited warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Limitation of Remedies In no event shall Philips be liable for any special, incidental or consequential damages based upon breach of warranty, breach of contract, negligence, tort, or any other legal theory. Such damages include, without limitation, loss of savings or revenue, loss of profit, loss of use, the claims of third parties, and cost of any substitute equipment or services. Some states do not allow the exclusion or limitations of incidental or consequential damages so the above limitation or exclusion may not apply to you.
Returns Policy

Product returns require the Seller’s prior written permission and issuance of a return material authorization number (RMA) before any product is returned and must be within 30 days. Contact the factory in your country for an RMA number. The factory will review your request. All approved returns must include the original invoice number, freight must be prepaid, and the return must be received less than 6 months after the original shipment date. Seller has the right to refuse to accept the return of any goods. Goods that are made to order, special orders, of obsolete design, or used goods will not be accepted for return. All return credits, if, as, and when issued, and except in the case of Seller’s shipping error, will be subject to Seller’s normal minimum return charge of 30% . Final acceptance of returned goods is subject to examination at the factory, including such examination as is required to determine the condition of goods. All returned goods remain the customer’s property and responsibility until such time (if any) as a credit memo has been issued. Seller will notify Buyer with reasonable promptness if a decision has been made not to issue credit. Any refund issued will be less freight any and all applicable freight charges. Any debit note amount that is deducted from payment without an accompanying Seller-issued credit note will be re-invoiced with a $50.00 surcharge for each debit note item, plus any applicable interest charges. In such cases it will then be Buyer’s responsibility to provide disposal instructions within five days, failing which returned product and materials will be scrapped. *Unfortunately, due to hygiene reasons, fabric face masks may not be returned once shipped.

Shipping

Our goal is to service all customers, regardless of their nationwide location, in a convenient manner and reasonable time frame.

To achieve this we currently operate a corporate warehouse located in Calgary, AB.

We also work tirelessly to establish strategic partnerships in metro cities and outside our borders to ensure consistent and reliable inventory supply.

Each product line we carry is diverse in terms of size, weight and handling requirements. Because of this we offer a number of delivery options to our customers allowing them to choose the method which meets their needs more closely.

All orders which require shipping to a customer will automatically be sent prepaid with Canada Post unless otherwise specified. Freight charges vary depending on your shipment weight & dimensions, destination address and shipping agreement in place at time of order. If you would like to make alternative shipping arragements please be sure to contact our friendly customer care staff at 1-800-260-6362.

*Unfortunately, due to hygiene reasons, fabric face masks may not be returned once shipped.

Related Products